{"id":12297,"date":"2020-05-14T13:09:52","date_gmt":"2020-05-14T13:09:52","guid":{"rendered":"https:\/\/rfid4u.com\/?page_id=12297"},"modified":"2024-11-06T12:05:01","modified_gmt":"2024-11-06T12:05:01","slug":"cheat-sheet-deployment-steps","status":"publish","type":"page","link":"https:\/\/rfid4u.com\/cheat-sheet-deployment-steps\/","title":{"rendered":"Cheat Sheet \u2013 RFID Deployment Steps"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_section full_width=&#8221;stretch_row&#8221; css=&#8221;.vc_custom_1589438219221{background-image: url(https:\/\/rfid4u.com\/wp-content\/uploads\/2020\/05\/background.png?id=11905) !important;background-position: center !important;background-repeat: no-repeat !important;background-size: cover !important;}&#8221;][vc_row][vc_column][vc_custom_heading text=&#8221;Preparation for RFID Certification Exam&#8221; font_container=&#8221;tag:h5|text_align:center|color:%23ffffff&#8221; use_theme_fonts=&#8221;yes&#8221;][vc_custom_heading text=&#8221;Cheat Sheet \u2013 RFID Deployment Steps&#8221; font_container=&#8221;tag:h1|text_align:center|color:%23ffffff&#8221; use_theme_fonts=&#8221;yes&#8221;][\/vc_column][\/vc_row][\/vc_section][vc_section el_class=&#8221;default-list&#8221;][vc_row gap=&#8221;30&#8243;][vc_column width=&#8221;1\/2&#8243;][vc_custom_heading text=&#8221;MAIN OBJECTIVES&#8221; font_container=&#8221;tag:h3|text_align:left|color:%230f4996&#8243; use_theme_fonts=&#8221;yes&#8221;][vc_column_text]<\/p>\n<ul>\n<li>Know the steps to deploy RFID Solution<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>The basic steps that should be taken to ensure that other radio equipment will not interfere with an RFID deployment?<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>The basic steps that should be taken to ensure that other electrical equipment will not interfere with an RFID deployment?<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Understand the role of \u201cmiddleware\u201d in retrieving RFID\u00a0data\u00a0from the reader and passing it on to the system that will eventually process or use it.<\/li>\n<\/ul>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;80px&#8221;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_row_inner content_placement=&#8221;middle&#8221; css=&#8221;.vc_custom_1589440356193{border-left-width: 3px !important;padding-top: 20px !important;padding-right: 20px !important;padding-bottom: 0px !important;padding-left: 20px !important;background-color: #f6f6f6 !important;border-left-color: #ff871c !important;border-left-style: solid !important;border-radius: 5px !important;}&#8221;][vc_column_inner][vc_custom_heading text=&#8221;Download the Cheat Sheet in PDF&#8221; font_container=&#8221;tag:p|text_align:left&#8221; use_theme_fonts=&#8221;yes&#8221;][vc_btn title=&#8221;Download&#8221; style=&#8221;custom&#8221; custom_background=&#8221;#ff871c&#8221; custom_text=&#8221;#ffffff&#8221; link=&#8221;url:%2Fwp-content%2Fuploads%2F2016%2F06%2F9-Cheat-Sheet-Deployment-Steps.pdf&#8221;][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row gap=&#8221;30&#8243;][vc_column][vc_custom_heading text=&#8221;STEPS TO DEPLOY AN RFID SOLUTION&#8221; font_container=&#8221;tag:h2|text_align:left|color:%23000000&#8243; use_theme_fonts=&#8221;yes&#8221;][vc_empty_space][\/vc_column][\/vc_row][vc_row gap=&#8221;30&#8243;][vc_column width=&#8221;1\/2&#8243;][vc_custom_heading text=&#8221;1. SITE ASSESSMENT AND SITE SURVEY&#8221; font_container=&#8221;tag:h3|text_align:left|color:%230f4996&#8243; use_theme_fonts=&#8221;yes&#8221;][vc_column_text]<\/p>\n<div class=\"wpb_text_column wpb_content_element \">\n<div class=\"wpb_wrapper\">\n<p>All the needs are determined during a site and workflow assessment:<\/p>\n<div class=\"su-list\">\n<ul>\n<li><i class=\"sui sui-caret-right\"><\/i>Current data collection\u00a0<strong>system assessment and business process analysis<\/strong>\u00a0\u2013 determines the current systems used and processes deployed, their strengths and weaknesses<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i><strong>A site survey<\/strong>\u00a0\u2013 provides a physical review, analysis, recommendations and report by qualified RFID Engineers of the site where RFID infrastructure and equipment will be installed so that the RFID processes work 100% of the time<\/li>\n<\/ul>\n<\/div>\n<p><strong>The basic steps that should be taken to ensure that other radio equipment will not interfere with an RFID deployment?<\/strong><\/p>\n<div class=\"su-list\">\n<ul>\n<li><i class=\"sui sui-caret-right\"><\/i>A \u201cSite Survey\u201d to establish what other radio equipment may be in use<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Figure out which part of the RFID radio spectrum in use may be impacted<\/li>\n<\/ul>\n<\/div>\n<p><strong>The basic steps that should be taken to ensure that other electrical equipment will not interfere with an RFID deployment?<\/strong><\/p>\n<div class=\"su-list\">\n<ul>\n<li><i class=\"sui sui-caret-right\"><\/i>A \u201cSite Survey\u201d to establish what electrical equipment may be in use and whether or not it is creating\u00a0Electromagnetic Interference (EMI)<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Assess if any EMI present is sufficient to degrade the RFID system performance<\/li>\n<\/ul>\n<\/div>\n<p>Site survey describes the whole process of site assessment that determines the needs of the customers, and provides information based upon the system will be designed and deployed.<\/p>\n<p>Some, call a site survey only the part of the whole site assessment where the possible radio or EMI\u00a0interference\u00a0is determined, which is performed by using\u00a0<strong>a spectrum analyzer.<\/strong><\/p>\n<\/div>\n<\/div>\n<div class=\"wpb_text_column wpb_content_element \">\n<div class=\"wpb_wrapper\">\n<p><strong>The Site Assessment also includes review of environmental conditions:<\/strong><\/p>\n<div class=\"su-list\">\n<ul>\n<li><i class=\"sui sui-caret-right\"><\/i><strong>Weather<\/strong>\u00a0(outside) \u2013 rain, snow, wind, temperature, humidity<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i><strong>Type of Facility<\/strong>\u00a0\u2013 industrial \/ business, Store front, Clean room<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i><strong>Condition within the Facility<\/strong>\u00a0\u2013 temperature extremes, humidity, chemicals, industrial dust \/ lint, vibration, motion \/ movement<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i><strong>Location of \u2013\u00a0<\/strong>heavy machinery, conveyor belts, restricted zones by machines<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i><strong>Emissions from Machines:<\/strong>\n<ul>\n<li><i class=\"sui sui-caret-right\"><\/i>Heat, steam, chemicals \u2013 will damage hardware<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Electromagnetic Field\u00a0(EMF) and Electromagnetic Interference (EMI) \u2013 will affect system performance and reading tags by interfering with the RF signal<\/li>\n<\/ul>\n<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i><strong>Type of storage shelves and cabinets\u00a0<\/strong>(metal shelving will block\/reflect RF)<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<p>[\/vc_column_text][vc_empty_space][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_custom_heading text=&#8221;2. PRE-INSTALLATION&#8221; font_container=&#8221;tag:h3|text_align:left|color:%230f4996&#8243; use_theme_fonts=&#8221;yes&#8221;][vc_column_text]<\/p>\n<ul>\n<li>Preassemble portals and other RFID and mounting hardware before arriving on site if possible<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>An installer will need basic hand tools, power tools, tie wraps, beam clamps and fasteners, etc.<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Check equipment inventory \u2013 Hardware, cables, mounting devices<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Provide RFID Fixed Reader protection\n<ul>\n<li><i class=\"sui sui-caret-right\"><\/i>Using a NEMA-4<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Using only light plastic enclosures<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Reader embedded in a portal<\/li>\n<\/ul>\n<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Verify cable lengths for\u00a0antenna\u00a0at each\u00a0read\u00a0point<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Confirm antenna, power and network cabling for each read point are correct<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Ensure reader accessibility for maintenance checks<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Verify multiplexing sequences of readers<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Confirm criteria for determining a\u00a0tag\u00a0is read<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Review reader placement to ensure close\u00a0proximity\u00a0to the antennas they power<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Position triggering devices \u2013 Where are they to be mounted?<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Verify\n<ul>\n<li><i class=\"sui sui-caret-right\"><\/i>Power and ground connections<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Environmental protection<\/li>\n<\/ul>\n<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Any facilities work must be completed prior to the scheduled installation date:\n<ul>\n<li><i class=\"sui sui-caret-right\"><\/i>Holes in walls for cables<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Special brackets or antenna masts<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Enclosures<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Bollards<\/li>\n<\/ul>\n<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Network cabling\/infrastructure must meet industry standards\n<ul>\n<li><i class=\"sui sui-caret-right\"><\/i>Ensure reader\u2019s status indicator LEDs are easily visible to an operator<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Validate fixed reader status indicators: green for success, amber for on-going and red for failure<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Check for environmental conditions (even though this has been done at the site survey, something could have changed or not have been accounted for)<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row][vc_row gap=&#8221;30&#8243;][vc_column width=&#8221;1\/2&#8243;][vc_custom_heading text=&#8221;3. INSTALLATION&#8221; font_container=&#8221;tag:h3|text_align:left|color:%230f4996&#8243; use_theme_fonts=&#8221;yes&#8221;][vc_column_text]<strong>Antenna<\/strong><\/p>\n<div class=\"su-list\">\n<ul>\n<li><i class=\"sui sui-caret-right\"><\/i>Connect an antenna to a reader only when it is powered off<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>\u00a0Do not disconnect the antenna when \u2018read\u2019 is on<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>\u00a0Protect antenna installations with a guard<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Tilt the antenna to extend the read zone<\/li>\n<\/ul>\n<\/div>\n<p><strong>Reader<\/strong><\/p>\n<div class=\"su-list\">\n<ul>\n<li><i class=\"sui sui-caret-right\"><\/i>Mount readers securely so that they are not disturbed, bumped or damaged<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>As a rule of thumb leave 5 to 6 inches of clearance on all sides of a reader (for ventilation and access purposes)<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Place\/orient readers correctly, according to the recommendations of manufacturers<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Some readers may have environmental enclosures for protection. Place them accordingly<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Place readers so that its status indicator lights or LEDs are easily visible to an operator<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Reader ports that are not in use, should not be activated<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Never power up an antenna port when not in use<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Use surge protector for power<\/li>\n<\/ul>\n<\/div>\n<p><strong>Cables<\/strong><\/p>\n<div class=\"su-list\">\n<ul>\n<li><i class=\"sui sui-caret-right\"><\/i>Select the best RF cables for the application<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Know cable attenuation in dB\/m<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Impedance has to match antenna and reader impedance<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>If RF cables are stiff\/inflexible, secure them correctly so that they are not under mechanical stress<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Coil up extra cable lengths<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Place equal cable lengths from reader to antenna pairs<\/li>\n<\/ul>\n<\/div>\n<p><strong>Tagged items<\/strong><\/p>\n<div class=\"su-list\">\n<ul>\n<li><i class=\"sui sui-caret-right\"><\/i>Ensure that the tagged\u00a0item\u00a0does not travel too close to an antenna; it should avoid antenna near fields.<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Place markers\/guards accordingly, near the antenna positions<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Ensure that the tag and the reader have direct line of sight for\u00a0UHF. Tags in between cartons may not be detected<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Position the tags on the outside of the pallet load. Avoid overlapping labels.<\/li>\n<\/ul>\n<\/div>\n<p>[\/vc_column_text][vc_empty_space][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_custom_heading text=&#8221;4. MIDDLEWARE&#8221; font_container=&#8221;tag:h3|text_align:left|color:%230f4996&#8243; use_theme_fonts=&#8221;yes&#8221;][vc_column_text]All readers have to be connected to the network and configured properly to communicate with the middleware and back-end systems.<\/p>\n<div class=\"su-list\">\n<ul>\n<li><i class=\"sui sui-caret-right\"><\/i>Manages hardware devices and communicates between readers and business applications.<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>It\u2019s a set of many different distributed software elements: Event Management, Data Conversion, Database Management, Data Consolidation, Data Reporting, etc.<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Refers to all the software between the on-device software and the business applications.<\/li>\n<\/ul>\n<\/div>\n<p>[\/vc_column_text][vc_empty_space][vc_custom_heading text=&#8221;MIDDLEWARE FUNCTIONS&#8221; font_container=&#8221;tag:h5|text_align:left|color:%230f4996&#8243; use_theme_fonts=&#8221;yes&#8221;]<div class=\"radiantthemes-accordion element-three   rt1711832895\"  ><div class=\"radiantthemes-accordion-item\"><div class=\"radiantthemes-accordion-item-title\"><div class=\"radiantthemes-accordion-item-title-icon\"><i class=\"fa fa-angle-down\"><\/i><\/div><h4 class=\"panel-title\">SUPPORT READ\/WRITE DEVICES<\/h4><\/div><div class=\"radiantthemes-accordion-item-body\"><\/p>\n<ul>\n<li class=\"\">Tag\/reader agnostic<\/li>\n<li class=\"\"><i class=\"sui sui-caret-right\"><\/i>Management console<\/li>\n<\/ul>\n<p><\/div><\/div><div class=\"radiantthemes-accordion-item\"><div class=\"radiantthemes-accordion-item-title\"><div class=\"radiantthemes-accordion-item-title-icon\"><i class=\"fa fa-angle-down\"><\/i><\/div><h4 class=\"panel-title\">EVENT DATA MANAGEMENT<\/h4><\/div><div class=\"radiantthemes-accordion-item-body\">Retrieve data from the readers, perform light processing, and pass the data to the back-end system. Data processing involves:<\/p>\n<div class=\"su-list\">\n<ul>\n<li><i class=\"sui sui-caret-right\"><\/i>Cleanse data \u2013 eliminate\u00a0redundancy\u00a0and smooth missed reads<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Filter data \u2013 based on product or time stamp<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Massage data \u2013 aggregate, summarize, correlate<\/li>\n<\/ul>\n<\/div>\n<p><\/div><\/div><div class=\"radiantthemes-accordion-item\"><div class=\"radiantthemes-accordion-item-title\"><div class=\"radiantthemes-accordion-item-title-icon\"><i class=\"fa fa-angle-down\"><\/i><\/div><h4 class=\"panel-title\">EPC HANDLING<\/h4><\/div><div class=\"radiantthemes-accordion-item-body\"><\/p>\n<ul>\n<li>Provisioning<\/li>\n<li class=\"\"><i class=\"sui sui-caret-right\"><\/i>Format negotiation<\/li>\n<\/ul>\n<p><\/div><\/div><div class=\"radiantthemes-accordion-item\"><div class=\"radiantthemes-accordion-item-title\"><div class=\"radiantthemes-accordion-item-title-icon\"><i class=\"fa fa-angle-down\"><\/i><\/div><h4 class=\"panel-title\">EVENT RECOGNITION<\/h4><\/div><div class=\"radiantthemes-accordion-item-body\"><\/p>\n<ul>\n<li>Rules based<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Exception driven<\/li>\n<\/ul>\n<p><\/div><\/div><div class=\"radiantthemes-accordion-item\"><div class=\"radiantthemes-accordion-item-title\"><div class=\"radiantthemes-accordion-item-title-icon\"><i class=\"fa fa-angle-down\"><\/i><\/div><h4 class=\"panel-title\">TASK MANAGEMENT<\/h4><\/div><div class=\"radiantthemes-accordion-item-body\"><\/p>\n<ul>\n<li>Directed activity<\/li>\n<li>Light logic<\/li>\n<\/ul>\n<p><\/div><\/div><div class=\"radiantthemes-accordion-item\"><div class=\"radiantthemes-accordion-item-title\"><div class=\"radiantthemes-accordion-item-title-icon\"><i class=\"fa fa-angle-down\"><\/i><\/div><h4 class=\"panel-title\">BUFFER I\/O ACTIVITY<\/h4><\/div><div class=\"radiantthemes-accordion-item-body\"><\/p>\n<ul>\n<li>Cluster reads<\/li>\n<li>Tag data updates<\/li>\n<\/ul>\n<p><\/div><\/div><\/div>[vc_empty_space][vc_custom_heading text=&#8221;What type of data could be available from the reader:&#8221; font_container=&#8221;tag:h5|text_align:left|color:%230f4996&#8243; use_theme_fonts=&#8221;yes&#8221;][vc_column_text]<\/p>\n<ul>\n<li>Identity of the item observed by the RFID system<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>The reader\/antenna combination that observed the item<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>When the observation was made (date and time stamp)<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>The strength of the signal that was returned by the item<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>How many times the item\u2019s RFID tag was read<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Protocol\u00a0of the tag<\/li>\n<li><i class=\"sui sui-caret-right\"><\/i>Tag ID<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][\/vc_section]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_section full_width=&#8221;stretch_row&#8221; css=&#8221;.vc_custom_1589438219221{background-image: url(https:\/\/rfid4u.com\/wp-content\/uploads\/2020\/05\/background.png?id=11905) !important;background-position: center !important;background-repeat: no-repeat !important;background-size: cover !important;}&#8221;][vc_row][vc_column][vc_custom_heading text=&#8221;Preparation for RFID Certification Exam&#8221; font_container=&#8221;tag:h5|text_align:center|color:%23ffffff&#8221; use_theme_fonts=&#8221;yes&#8221;][vc_custom_heading text=&#8221;Cheat Sheet \u2013 RFID Deployment Steps&#8221; font_container=&#8221;tag:h1|text_align:center|color:%23ffffff&#8221; use_theme_fonts=&#8221;yes&#8221;][\/vc_column][\/vc_row][\/vc_section][vc_section el_class=&#8221;default-list&#8221;][vc_row gap=&#8221;30&#8243;][vc_column width=&#8221;1\/2&#8243;][vc_custom_heading text=&#8221;MAIN OBJECTIVES&#8221; font_container=&#8221;tag:h3|text_align:left|color:%230f4996&#8243; use_theme_fonts=&#8221;yes&#8221;][vc_column_text] Know the steps to deploy RFID Solution The basic steps that should be taken to ensure that other radio equipment will not [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"om_disable_all_campaigns":false,"inline_featured_image":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-12297","page","type-page","status-publish","hentry"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/rfid4u.com\/wp-json\/wp\/v2\/pages\/12297","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/rfid4u.com\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/rfid4u.com\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/rfid4u.com\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/rfid4u.com\/wp-json\/wp\/v2\/comments?post=12297"}],"version-history":[{"count":2,"href":"https:\/\/rfid4u.com\/wp-json\/wp\/v2\/pages\/12297\/revisions"}],"predecessor-version":[{"id":19443,"href":"https:\/\/rfid4u.com\/wp-json\/wp\/v2\/pages\/12297\/revisions\/19443"}],"wp:attachment":[{"href":"https:\/\/rfid4u.com\/wp-json\/wp\/v2\/media?parent=12297"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}